Use wire leads when the fan assembly needs a routed harness, and blade terminals when it uses a matching quick-connect plug. Both versions still need the fan’s specified electrical rating. The connection drawing determines which wires or terminal groups belong to each capacitor section.
Start with the fan assembly
Two fan versions can share a CBB61 capacitance value and still need different harnesses. One places the capacitor beside the terminal block; another routes its leads through a narrow housing. Specify each harness against the fan model and connection drawing so each order line identifies the right assembly.
Specify what the connector actually mates with
A lead specification includes finished length, measurement points, exit direction, conductor arrangement and end termination. For a crimped connector, identify the mating part or its drawing. An extra length allowance can solve routing problems, but loose cable also needs enough protected space inside the enclosure.
For quick-connect blades, the relevant dimensions are width, thickness, spacing and position relative to the case. A nominal terminal width alone does not establish a reliable fit. The installed female connector adds height and needs room for insertion and removal.
Wire-lead housings and a mounting tab
The photograph shows the lead exits and fixing features. Use the model drawing and datasheet for dimensions and electrical ratings.
Wire colors do not identify a circuit
A replacement with the same wire count can have a different internal connection. This is particularly important on fan-speed assemblies with several capacitance sections. The motor wiring diagram and the capacitor connection drawing establish the section values and common connections; colors alone cannot do that.
The blade-terminal samples shown here are marked 4.5 µF, 5 µF and 6 µF at 450 VAC. The red wire-lead housings show a different connection and mounting format. Their electrical ratings are not documented in the supplied photograph.
Three individual CBB61 ratings
Each housing contains a separate capacitor with the nominal value printed on its label.
Approve the part with the fan cover closed
The installed envelope includes case length, width and height, mounting-tab holes, screw clearance and the connected harness. A component can fit on an open bench and foul the cover after the plug is fitted. A mounted sample makes that interference visible before a bulk order.
Keep the approved lead length, connector and drawing revision with the sample reference. If any of those changes, review the affected fit again. Electrical or structural changes to HAN XING models are quoted by model; label and packaging customization have a separate artwork approval.
Get the connection drawing for your fan
Include the original connection photo, motor diagram and required lead or connector details.